IBM mainframe capacity-based licensing decides how much of a machine you pay to license, and the three available models can produce very different bills on the same workload. Full capacity charges you for the machine’s rated capacity whether you use it or not, while sub-capacity charges you for measured peak usage provided you meet the reporting conditions. Tailored Fit Pricing charges you against a negotiated baseline built from your own reporting history.

Below we cover how each of the capacity-based licensing models works, how SCRT measures usage for sub-capacity, which IPLA products qualify and how their capacity is derived, the products excluded from sub-capacity altogether, and what to establish before committing to Tailored Fit Pricing.
The Three IBM Mainframe Capacity-Based Licensing Models
IBM offers three capacity-based licensing models: full capacity, sub-capacity, and Tailored Fit Pricing. They aren’t alternatives you can switch between freely, because each carries its own eligibility conditions and reporting obligations, and some products are locked to one of them.
Full Capacity Licensing
Full capacity is the oldest of the capacity-based licensing models and the simplest to describe. Pricing is based on the machine’s rated capacity, which is determined by its model, and the charge remains constant regardless of how much you use the software. If a product is identified as deployed anywhere in your environment, it’s charged at the machine’s rated capacity.
That’s the position you fall back to if you don’t qualify for anything else, or if you stop meeting the conditions for sub-capacity partway through. Understanding what full capacity would cost on your machines is worth doing for that reason alone, since it’s the number you’re exposed to when reporting slips.
Sub-Capacity Licensing and How SCRT Measures It
IBM introduced sub-capacity licensing in 2000. Instead of charging for the machine’s rated capacity, it prices software on the MSUs a particular product uses on the LPAR or LPARs where it runs. The approach parallels IBM’s virtualization capacity licensing on the distributed side of the portfolio.
Measurement under sub-capacity licensing is provided by SCRT (the Sub-Capacity Reporting Tool), which IBM provides at no charge. SCRT reports the MSUs of eligible sub-capacity products each month based on peak consumption using a Rolling 4-Hour Average. It covers products running on z/OS, z/VSE, and z/TPF, and the MSU figures it produces are used to calculate your sub-capacity charges.
How the Rolling 4-Hour Average is calculated
Workload Manager monitors MSU usage for each LPAR every 10 seconds. Every five minutes, it records the peak MSU usage from the 10-second intervals and retains the most recent 48 of those five-minute records. As each new record arrives, the oldest is discarded, producing a rolling window over the past 4 hours (240 minutes). The average of those 48 samples is stored in the WLM control block as the Rolling 4-Hour Average.
SCRT then cross-references LPAR utilization against product execution to find the highest combined four-hour rolling average across the LPARs where a given product runs, so a product spread over several LPARs is measured on their concurrent peak rather than on any one of them. The monthly report covers the period from midnight on the first day of one month to midnight on the first day of the next, and identifies the peak R4HA hour within that window. That single peak value is the basis for the month’s software billing. Because the measure is a four-hour average, a brief spike gets diluted across the window, but a peak sustained long enough to lift that average sets the charge for the entire month.
Conditions you have to meet
Sub-capacity licensing depends on three conditions being met, and you must own all three.
- SCRT has to be available. It ships with z/OS 2.3 and later, and it can be downloaded for earlier releases or to run on Windows or Linux.
- You have to generate an SCRT report every month.
- Each report has to reach IBM through License Management Support by the ninth day of the month following the reporting period.
Missing a single month’s submission means you lose the sub-capacity benefit for that month and get charged on the machine’s rated full capacity instead. The cost of that depends on how far your measured usage falls below the machine’s rating, and it arises from an administrative lapse rather than anything related to your deployment.
What SCRT leaves out
Products running on z/VM fall entirely outside SCRT reporting. They’re licensed by engine count rather than by MSU, which is covered further down.
IPLA Sub-Capacity Eligibility
Certain IPLA products qualify for sub-capacity, and they fall into three groups. Which group a product belongs to determines how its sub-capacity MSU figure is derived, and only one of the three appears directly in SCRT.
IPLA execution-based products
These appear in the SCRT report, and the sub-capacity value comes from the peak Rolling 4-Hour Average usage of the product itself. IBM publishes the list of IPLA execution-based products.
IPLA z/OS-based products
These don’t appear in the SCRT report at all. Their sub-capacity value is taken from the peak Rolling 4-Hour Average MSUs reported in SCRT for the parent product, which is z/OS base, an MLC product whose usage SCRT does record. IBM publishes the parent product IDs for IPLA z/OS-based products.
IPLA reference-based products
These also fall outside the SCRT report, and their sub-capacity value comes from the peak Rolling 4-Hour Average MSUs reported for a parent product, which will be CICS, Db2 or IMS. Those parent programs are usually MLC products, though in some cases they can be IPLA Value Unit Edition variants instead. IBM publishes the parent product mapping for IPLA reference-based programs.
There’s a sysplex rule on this group worth establishing before you model anything. Where an IPLA reference-based product is in use within a Parallel Sysplex, the required license capacity is the total MSU capacity across the whole sysplex, not the capacity of the machine the product runs on. IBM’s Value Unit Exhibits work on a sliding scale, so a larger required license capacity means fewer Value Units per MSU, and Parallel Sysplex separately affects your price through aggregation. Work out the quantity under this rule and both price effects together rather than assuming one tells you about the others.
IPLA z/VM-Based Products
Licensing for IPLA z/VM-based products is based on engines or processors rather than on MSUs, and the applicable Value Unit Exhibit is VUE021. Licensing is per machine, so a VUE021 product deployed on one machine but not another requires licensing only the engines on the first machine.
z/VM runs on Central Processor engines, and it can also run on Integrated Facility for Linux engines when executing Linux or Open Solaris workloads. CPs and IFLs are counted separately when working out how many engines need licensing.
For z/VM base and its optional, priced features, including RACF Security Server for z/VM and Performance Toolkit for z/VM, the IPLA full-capacity rules apply as follows.
- Using the product on any CP on a machine means all CPs on that machine have to be licensed.
- Using it on any IFL means all IFLs on that machine have to be licensed, and IFLs are restricted to Linux and Open Solaris workloads.
- When the product runs only on CPs, the number of IFLs does not affect the requirement.
- Where it runs only on IFLs, the number of CPs makes no difference.
When the rule says all CPs or all IFLs on a machine, that means assigned engines, whatever they’re currently doing. Engines you’ve purchased but haven’t assigned, sometimes called banked engines, don’t count, because they aren’t physically available to be used.
Sub-capacity pricing for z/VM
Falling outside SCRT doesn’t mean z/VM is stuck at full capacity. IBM offers a separate sub-capacity option for eligible z/VM programs, measured via a Hypervisor Proxy running in each z/VM LPAR rather than via SCRT. Each eligible program is licensed under either the terms that apply to the z/VM hypervisor and its features or under z/VM-Based terms, and IBM decides which.
Establish which of your z/VM programs are eligible before you assume the full capacity engine counting rules above are the only option open to you.
Products That Can’t Use Sub-Capacity
Some products are excluded from sub-capacity licensing regardless of your reporting, and knowing which ones prevents you from building a cost case around a saving that can’t happen. Eligibility under capacity-based licensing depends on the metric a product carries, so confirm it per product before you put a saving in a business case. Some products also use different capacity algorithms, including those adjusted by Integrated Workload Pricing and those eligible for Getting Started Sub-Capacity Pricing, so the standard calculation doesn’t apply universally.
On the MLC side, a few metrics are full capacity only, including Parallel Sysplex License Charges and z Entry License Charges. Flat Workload License Charge products carry a single fee per product per eligible machine regardless of the machine’s capacity, so sub-capacity measurement doesn’t change what you pay on them. On the IPLA side, IBM lists some products with sub-capacity eligibility marked as Not Eligible, and those can only be charged at full capacity.
Tailored Fit Pricing
IBM introduced Tailored Fit Pricing in 2019 as a consumption-based option. Under the Software Consumption solution, utilization is tracked and totaled hourly rather than through a rolling average, which IBM presents as removing the cost escalation that workload spikes can cause under R4HA billing.
How the baseline is set
IBM requests your SCRT reports for the past 12 months and builds a baseline from them. It calculates a price per MSU by analyzing your total MSU consumption and MLC charges for that year. The contract then typically runs three to five years with an annual MSU allocation based on that baseline.
Read that mechanism carefully, because the baseline comes from data you produced and submitted. If those 12 months overstated your consumption, whether through a one-off project peak or a reporting error, the annual MSU allocation IBM sets from them commits you to more capacity than you need for the length of the contract. Validating the last year of SCRT output before IBM builds a baseline from it is worth doing for that reason alone.
What happens to unused and excess MSUs
Unused MSUs at the end of a year carry over into the following year. Any that remain unused at the end of the contract are forfeited. If you exceed your annual commitment, the excess is billed at the per-MSU price agreed in the contract.
The commitment therefore works in IBM’s favor at both ends. Consuming less than you committed to results in a carryover that eventually expires without a refund, and consuming more results in a bill at the excess rate. Both outcomes trace back to the accuracy of the baseline, so the consumption forecast behind it warrants as much attention as the monthly figure on the proposal.
Conditions for Tailored Fit Pricing
- SCRT has to be available and running.
- You have to generate monthly SCRT reports.
- Those reports have to be submitted to IBM.
- 12 months of SCRT reports must be available for IBM to build a baseline.
Modeling a TFP baseline against your own validated consumption before negotiating it is a core part of our IBM mainframe negotiation work.
Useful Mainframe References
The three IPLA product lists are linked above at the point each one applies. Two further IBM references are worth having to hand.
- IBM Z Software Pricing Tools, where SCRT is available to download.
- IPLA z/VM licensing, covering the engine counting rules for VUE021 products.
Conclusion
The three IBM mainframe capacity-based licensing models produce very different bills for the same workload, and which one you’re on depends on both product eligibility and whether you’ve kept up your side of the reporting. Sub-capacity is the model most estates should use and the one that’s easiest to lose through an administrative slip.
Tailored Fit Pricing shifts the question to a multi-year baseline built from data you supplied. Checking which capacity-based licensing model applies to each product and confirming the underlying reporting is where any mainframe cost work starts.
- Missing one monthly SCRT submission reverts that month to the machine’s rated full capacity.
- Only IPLA execution-based products appear directly in SCRT, and the other two groups derive their capacity from a parent product.
- PSLC and zELC are full capacity only, and Flat Workload License Charge products charge a flat fee per machine that sub-capacity measurement won’t reduce.
- A TFP baseline is built from your own last 12 months of SCRT reports, so validate them before IBM does.
FAQs
Full-capacity bills products against the machine’s rated capacity, so the charge doesn’t track usage. Sub-capacity bills against the peak Rolling 4-Hour Average MSUs that SCRT reports as in use across the month, which for most estates is considerably lower.
Workload Manager samples MSU usage every 10 seconds and records the peak from those samples every five minutes. The 48 most recent five-minute records, covering four hours, are averaged to produce the Rolling 4-Hour Average, and the window advances as new records replace the oldest. The peak R4HA hour in the monthly reporting period determines your billing.
SCRT ships with z/OS 2.3 and later. For earlier releases, or to run it on Windows or Linux, download it from the IBM Z Software Pricing Tools site. IBM provides the tool at no charge.
No, SCRT covers products running on z/OS, z/VSE and z/TPF only. That doesn’t mean z/VM is stuck at full capacity, because IBM runs a separate sub-capacity option for eligible z/VM programs measured through a Hypervisor Proxy in each z/VM LPAR. Where sub-capacity doesn’t apply, z/VM programs are licensed by engine count under VUE021.
You lose the sub-capacity benefit for that month, and the products are charged against the machine’s rated full capacity instead. IBM expects the report to be submitted through License Management Support by the ninth day of the month following the reporting period, so the deadline carries the same weight as the tooling.
No, only execution-based ones. IPLA z/OS-based products take their capacity from the SCRT figure for z/OS base, and IPLA reference-based products take theirs from the SCRT figure for CICS, Db2 or IMS depending on the product. Neither group is reported in its own right.
Sub-capacity bills each month against the peak Rolling 4-Hour Average that SCRT reports for that month. Tailored Fit Pricing bills against an annual MSU commitment set from a baseline IBM builds using your previous 12 months of SCRT data, with hourly totals rather than a rolling average, so the exposure shifts from monthly peaks to the accuracy of that baseline.