Parts of your IT estate may not connect directly to your software asset management server, which is normal in regulated environments. Banks, pharma companies, and others routinely run segmented networks, DMZs, and air gapped environments for security and compliance reasons. Both IBM and Flexera still expect regular, reliable inventory data from every server in scope, including those isolated machines.

Disconnected scanning is how both IBM and Flexera deal with those machines. It’s one of the most misunderstood parts of software asset management, and getting it wrong can leave you exposed during an IBM audit or with an inaccurate Flexera license position. This post explains what disconnected scanning is, why enterprises use it, and what configuring it entails for both the IBM License Metric Tool (ILMT) and the Flexera FlexNet Manager Suite.
What Is Disconnected Scanning
Disconnected scanning is a method for collecting software and hardware inventory from a computer that has no network connection to your central asset management server. Instead of the server reaching out to the endpoint, or the endpoint phoning home automatically, the scan runs locally on the machine. The results are packaged into a file and moved manually or via an approved transfer mechanism into the central tool for import and processing.
It typically applies to servers in a DMZ or restricted security zone, air gapped environments with no outbound internet or internal connectivity, mainframe partitions, IBM i (AS/400) systems and other platforms outside normal agent reach, production environments where firewall rules or change control make a direct agent connection impractical, and third-party hosted or managed infrastructure where the client controls the network boundary. Both IBM and Flexera support this scenario, but they approach it differently.
ILMT Disconnected Scanner
IBM License Metric Tool, now most commonly delivered as part of BigFix Inventory, normally relies on a BigFix agent installed on each managed computer to report usage back to the ILMT server. When a computer can’t run that agent or can’t reach the server, IBM provides a disconnected scanner instead.
The disconnected scanner is a standalone component. It’s installed directly on the target computer and runs software and capacity scans locally, without needing a live connection to the ILMT server. The results are written to a package file. From there, you either upload the package automatically, if the computer has some form of connectivity, even through a proxy, by configuring the server URL and an API token, or you move the package manually, for example, by secure file transfer, into a disconnected data source directory that you create on the ILMT server.
On the server side, you create a Data Source of type Disconnected and point it to that directory. ILMT then imports the packages from there on a scheduled or manual basis, just as it would import data from a connected agent.
The scanner itself runs on a fixed schedule once installed. Hardware, or capacity, scans run automatically every 30 minutes and use less than 1% processor utilization, so they have a negligible impact on the server. Software scans run weekly by default and can use up to 100% CPU unless a threshold is configured, so they’re worth scheduling deliberately on production systems rather than leaving them on the default setting.
Result packages are generated on the software scan schedule rather than the capacity scan schedule. Each package bundles all hardware and software results gathered since the previous package was created, so a missed upload delays every result collected since the last successful transfer. IBM recommends uploading the resulting data packages daily or at least weekly to remain compliant. A scanner that has been running for months on an endpoint from which nobody is uploading gives you no audit protection at all.
If the default schedule or CPU usage limits don’t suit a particular server, both can be adjusted through the scanner’s configuration parameters, covered in IBM and HCL Software’s documentation on disconnected scanner configuration.
This approach is why ILMT disconnected scanning is so important for IBM sub-capacity licensing. If a server running IBM software is never scanned, IBM’s default position in an audit is full-capacity licensing for that machine, which is almost always far more expensive than sub-capacity licensing. A missed or broken disconnected scan, even on a handful of servers, can translate into a significant compliance gap.
ILMT also supports disconnected scanning for IBM i (AS/400) and other platforms where a standard agent isn’t available, using the same package and import logic.
Flexera Disconnected Mode
Flexera FlexNet Manager Suite uses a different architecture, built around inventory beacons rather than a single central agent. A beacon is a computer within your environment that gathers inventory from nearby systems and uploads it to the central FlexNet Manager Suite application server, whether on-premises or in the Flexera One cloud.
Disconnected mode applies at the beacon level. When a beacon itself has no route back to the central server, for example, because it’s in an isolated network segment or a fully air gapped enclave, it’s configured to operate independently. The beacon still performs its normal inventory collection role, but instead of pushing data straight to FlexNet Manager Suite, it stores the gathered inventory and configuration locally until it can be transferred.
At a high level, configuring a disconnected beacon means installing the inventory beacon software on a server inside the isolated network, configuring it to manage local inventory sources such as SCCM or its own discovery and inventory tasks without the connection to FlexNet Manager Suite enabled, periodically exporting the collected inventory data, transferring that data through an approved and secure channel to a beacon or environment that does have connectivity, and importing the data so it reaches the central application server and is reconciled into your overall license position.
Because Flexera’s beacon model is hierarchical, organizations sometimes use a connected beacon as a relay point, manually loading in data collected from one or more disconnected beacons further down the chain. It’s a common pattern in heavily segmented networks such as trading floors, OT environments, or strictly isolated production zones.
A disconnected beacon continues to collect inventory on its internal schedule, regardless of whether anyone is exporting it, just as the ILMT scanner does. The data is only useful once it’s transferred and imported, so the same daily or at a minimum weekly transfer routine that IBM recommends for ILMT is good practice for Flexera disconnected beacons too.
Key Differences Between ILMT and Flexera Disconnected Mode
| ILMT Disconnected Scanner | Flexera Disconnected Mode | |
| Applies at | Individual endpoint | Inventory beacon |
| Core purpose | IBM sub-capacity and PVU compliance evidence | General software and hardware inventory across any vendor |
| Data movement | Manual or scripted transfer of scan packages to a server-side data source | Manual or scheduled export and import between beacons or into the application server |
| Typical trigger | IBM audit risk reduction, sub-capacity reporting | Network segmentation, security policy, M&A integration, OT or air gapped zones |
Both tools assume connectivity by default. When that assumption doesn’t hold, each one needs a defined process for collecting and moving the data, and someone responsible for making sure it happens.
What Happens When Disconnected Scanning Breaks Down
Disconnected scanning often gets set up once during initial deployment and then forgotten. The scans keep running, but if nobody is uploading or importing the results, the gap goes unnoticed until an audit or a renewal exposes it.
For ILMT, a stalled or missed disconnected scan means IBM has no sub-capacity evidence for that server. In an audit, the default is full-capacity licensing for every processor core, not just the cores in use. For organizations running IBM software on large servers, this single gap can be the difference between a manageable true-up and a seven-figure exposure.
For Flexera, a disconnected beacon that stops exporting data, or whose exports aren’t reliably imported, creates blind spots in your license position. Those blind spots tend to surface at the worst possible time, usually during a renewal negotiation or an internal compliance review, when you discover the numbers you’ve been working from were never complete.
These failures are almost never technical. They happen when no one is clearly responsible for moving the data and confirming it arrived.
Signs You May Need a Disconnected Scanning Review
You’re likely affected if any of the following apply:
- You run production servers in a DMZ, an isolated VLAN, or an air-gapped enclave
- You have IBM i, mainframe partitions, or legacy Unix systems that fall outside your standard agent deployment
- A recent network segmentation, security hardening, or zero-trust initiative has cut off agent connectivity for some servers
- You’ve never independently verified that disconnected scan or beacon export packages are being imported and reconciled
- You’re preparing for an IBM ELA renewal, Passport Advantage true-up, or you’ve received audit correspondence from IBM
If two or more of these apply, disconnected scanning is a compliance control in your environment and needs to be managed as such.
How LicenseHawk Helps
LicenseHawk reviews ILMT and Flexera disconnected scanning configurations as part of our ILMT Health Check, SCRT Health Check, and internal IBM license review services. We check whether disconnected scans and beacon exports reach the central tool and are reconciled correctly, and we flag where gaps would surface in an IBM audit.
Because LicenseHawk is fully independent of IBM, with no reseller or referral relationship, our review is built around your commercial position, not IBM’s.
If you’re unsure whether your disconnected scanning setup would hold up in an IBM audit, an ILMT or SCRT Health Check will show you where the gaps are.
Further Reading
For teams who want to go deeper on the official configuration detail, these are the most useful primary sources:
- IBM Docs: Frequency of scans and uploads of data, the clearest official explanation of how scan and upload timing fits together
- IBM Docs: Disconnected scanner installation requirements, covering supported platforms and prerequisites before installing the scanner
- IBM Docs: Manually transferring disconnected scan results, for organizations that move packages by hand rather than through an automated upload
- HCL Software: Disconnected scanner configuration parameters, for adjusting CPU thresholds, schedules, and excluded directories
- Flexera Docs: Disconnected mode glossary entry, Flexera’s own definition and scope for disconnected beacons
Frequently Asked Questions
A normal ILMT setup relies on the BigFix agent to report inventory continuously to the ILMT server. A disconnected scanner is a standalone tool that runs locally on a computer with no server connectivity, producing a package of scan results that must be moved and imported separately.
ILMT is the mechanism IBM accepts as evidence of sub-capacity usage. If a server can’t be scanned, or its disconnected scan results aren’t imported, IBM has no evidence of sub-capacity and will typically default to full-capacity licensing for that machine during an audit.
Many organizations run beacons permanently in disconnected mode for fully air-gapped environments. The beacon continues to collect inventory locally, and data is exported and imported on a recurring schedule rather than in real time.
For ILMT, capacity scans run every 30 minutes, and software scans run roughly once a week by default. Result packages are tied to the software scan schedule, with each package containing all hardware and software results gathered since the previous one. IBM recommends uploading the resulting packages daily or at least weekly to keep the server-side data source current.
The same daily, or at a minimum weekly, transfer cadence is good practice for Flexera disconnected beacons. In both cases, the cadence only works if someone owns it and keeps it running, rather than setting it once and leaving it alone.
Capacity scans have a negligible footprint, using less than 1% processor utilization. Software scans are more intensive and can use up to 100% CPU unless a usage threshold is configured. On production servers, it’s worth reviewing the scanner’s configuration parameters and setting a CPU limit before relying on the default schedule, particularly on systems with tight performance margins.
The server or device effectively becomes invisible to your license position. For ILMT, that creates direct audit exposure. For Flexera, it creates a gap in your overall software inventory that can distort license consumption reporting across the estate.
Disconnected scanning extends well beyond air-gapped or high-security setups. It’s also commonly needed for IBM i and mainframe partitions, for servers undergoing network segmentation projects, and for environments acquired through mergers or acquisitions where network integration hasn’t yet been completed.
Most of our engagements involve reviewing an existing setup rather than building one from scratch. We check whether the configuration is working as intended and whether the data reaching IBM or Flexera reflects your true position